Participant-Specific Recognition of Grasp Type and Self-Scaled Effort Using Surface Electromyography: A Proof-of-Concept Study for Prosthetic Control in People with Congenital or Acquired Upper-Limb Absence
Objective. To assess participant-specific recognition of grasp type and subjectively scaled effort using surface electromyography in adults without upper-limb amputation, and unintended outputs during ordinary movements. This study is a preliminary step toward prosthetic control for people with congenital or acquired upper-limb absence. Methods. Four adults without upper-limb amputation performed eight command states: rest, open hand, and power grasp and tip pinch at low, medium and high verbally instructed effort. Effort categories were subjective; mechanical force was not measured. A separate linear discriminant analysis model was trained for each participant using time-domain features from consecutive signal windows, followed by causal majority voting over twenty windows. Evaluation comprised held-out trials separated from model fitting, newly recorded command trials processed causally, and ordinary movements without control intent; a confidence threshold of 0.60 was applied retrospectively to the latter. All recordings were obtained during one visit. No physical prosthesis was actuated. Results were summarized descriptively. Results. On held-out trials, mean balanced accuracy was 0.810 for raw windows, 0.823 after majority voting, and 0.875 for trial-level decisions. Among outputs with correctly recognized grasp type, effort recognition was more accurate for power grasp (0.970) than tip pinch (0.706). On newly recorded command trials, mean balanced accuracy was 0.902 and trial accuracy was 0.939; at the confidence threshold, coverage was 0.925 and end-to-end accuracy was 0.862. During ordinary movements, the mean proportion of unintended active outputs was 35.6% and decreased to 22.3% after confidence rejection, which retained 81.3% of outputs. The longest uninterrupted active-output episode after rejection lasted 7.25 seconds. Conclusion. The participant-specific decoder recognized instructed grasp and effort categories under controlled conditions. Unintended outputs during ordinary movements remain a concern for potential prosthetic use. These results do not establish clinical benefit or prosthesis control; evaluation with intended users, physical devices and functional tasks is needed.
Сведения
- Опубликовано
- 2026 · С. jto067
- Язык
- Английский
- ISSN
- 2789-9632 · 2789-9640
- Издатель
- National Scientific Center of Traumatology and Orthopaedics named after Academician N.D. Batpenov