Central AsianResearch Index

FRACTOGRAPHY OF IRRADIATED STEEL 0.12C18Cr10NiTi IN A BN-350 REACTOR AFTER MECHANICAL TESTS AT TEMPERATURES OF 350 AND 450 °C

The results are presented of a fractographic study of the fracture surface of samples of irradiated steel 0.12C18Cr10NiTi after tensile tests at temperatures of 24, 350, 450 °C. Samples for research were cut from the face of duct of spent fuel assemblies of fast neutron reactor BN-350. On the basis of a multilevel approach of physical mesomechanics, an attempt is made to explain the decrease in the ductility of steel with an increase in the temperature of mechanical tests. Based on the analysis results, it was concluded that a decrease in the ductility of steel with an increase in the test temperature may be due to quasi-uniform stress distribution in the area of localization of deformations, which was facilitated by the local increase in the porosity of the material caused by the accommodative processes of the rotary type.

Сведения

Журнал
NNC RK Bulletin
Опубликовано
2020 · № 3, С. 19-23
Язык
Английский
ISSN
1729-7516 · 1729-7885
Издатель
Republican State Enterprise "National Nuclear Center of the Republic of Kazakhstan
Аффилиации
Institute of Nuclear Physics Ministry of Energy RK