Indirect Determination of the Active Resistance and Temperature of the Stator Winding of an Asynchronous Generator
The indirect methods for calculating the temperature of asynchronous generators with the introduction of a pulse component in the power supply circuit of the stator windings of asynchronous generators with squirrel-cage rotor are considered. The relevance of this is sue is determined by the need to improve asynchronous energy converters to increase their reliability and safety. An indirect method for determining temperature based on measuring the resistance of the stator of an asynchronous generator with squirrel-cage rotor is proposed. The method is based on superimposing pulse signals of small amplitude and high frequency of 600 Hz on an alternating mains sinusoidal voltage with a frequency of 50 Hz. There were given the simulation results. The research results confirm the possibility of indirect tempera ture determination and the creation of a thermal protection system for asynchronous energy converters based on the use of estimation methods.
Сведения
- Журнал
- Trudy Universiteta
- Опубликовано
- 2024 · Т. 2, № 95
- Язык
- Английский
- ISSN
- 1609-1825 · 2710-3382
- Издатель
- Karaganda Technical University named after Abylkas Saginov