A method for improving the thermal schemes of steam turbine installations of thermal power plants with the replacement of one low-pressure surface-type heater with a mixing-type low-pressure heater is considered. The advantages and disadvantages of low-pressure surface and mixing type heaters are presented. A scheme for including a low-pressure mixing type heater in the regenerative heating system of a steam turbine plant is considered. The calculation of determining the additional power of the turbine plant when using a combined regeneration system was carried out. It presented that it is more efficient to use for regenerative water heating at thermal power plants mainly low-pressure surface heaters and, partially, mixing-type heaters. The use of a mixing-type heat exchanger in the thermal circuits of medium-power steam turbine plants leads to an increase in thermal efficiency and the efficiency of the thermodynamic cycle of the plant as a whole. An increase in the power of the turbine plant due to the elimination of undercooling in the heaters is shown.