Central Asian Research Index

Recent Contributions to Physics, 2019, т. 69, № 2, с. 61-70

Method for determining angles in x-ray emulsion chambers: Angle detection

S.B. Shaulov, N.O. Saduyev, D. Beznosko, O.A. Kalikulov, V.V. Zhukov, V.A. Ryabov, A.L. Shepetov, V.V. Piskal, E.S. Muhkamejanov, S.K. Shinbulatov, A.I. Zhumabayev, Sh.B. Utey, N.O. Yerezhep

P.N. Lebedev Physical Institute of the Russian Academy of Sciences; Moscow Institute of Physics and Technology (State University), MIPT (SU), Moscow, Russia
NNLOT, Al-Farabi Kazakh National University, Almaty, Kazakhstan
Bard Early College in New Orleans, New Orleans, LA 70117, USA
Al-Farabi Kazakh National University, Kazakstan, Almaty
P.N. Lebedev Physical Institute of the Russian Academy of Sciences, Moscow, Russia
National Nanolaboratory of Open Type, Al-Farabi KazNU, Almaty, Kazakhstan

Аннотация · Abstract

An analysis of the measurement procedure for the zenith and azimuth angles υ and φ in the X-ray emulsion chambers (XREC) of ADRON and PAMIR experiments is presented. Earlier, asymmetry was observed in distributions of azimuth angles of gamma and hadron families. A detailed analysis of methodological errors in measuring θ, φ angles allowed us to establish the causes of the distortion of azimuth angles distributions. There are two reasons: systematic errors in the measurement of zenith angles by MBS-2 microscopes, used both in the PAMIR experiment, and in the ADRON experiment, and the inclination of XREC based on the subsidence. Calculations showed that the total systematic error Δυ≈4 ° completely explains the observed azimuthal asymmetry. Formulas for correcting θ and φ angles are given. The recalculation of the angles by the indicated formulas showed that this corrects the distribution of the azimuthal angles φ. The REC plane should be set relative to the horizontal with an accuracy of no worse than 1 degree in order to avoid distortion of the angular distributions.

Сведения · Details